Strumento di monitoraggio polvere a diffrazione ottica certificato QAL1

QAL 360

Strumento di monitoraggio polvere certificato QAL1 da TUV e MCERTs utilizzabile da solo o opzionalmente in network con altri strumenti per una misurazione di alta precisione della concentrazione di polvere da processi industriali.

Avendo una scala certificata 0–7.5 mg/m3, il QAL 360 può essere usato con livelli di concentrazione sia bassi che alti soddisfando i requisiti per monitorare i limiti di emissione di 5 mg/m3 stabiliti dalla direttiva sulle emissioni industriali per i grandi impianti a combustione 2010/75/UE.

Certificato a 7,5 mg/m3

  • ProScatter™ Backscatter sensor technology with superior minimum detection <1 mg/m3
  • Certified to 7.5 mg/m3
  • Zero and Span (reference) checks available to ensure optimal instrument performance and compliant with QAL1
  • Automatic Contamination Check – fully interrogates the optical system
  • Purge Flow Fail Sensor option with inbuilt automatic optical shield activation
  • Flue Gas Blocker to protect Plant Engineers from harmful flue gases during maintenance
  • Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
  • Non-condensing / dry flue gases
    Typical Applications:

  • Incineration
  • Metals (eg Steel/Aluminium)
  • Minerals (eg Cement/Gypsum)
  • Chemicals (eg TiO2 / Coating Powder)
  • Power Generation Plant (eg Coal/Biomass)
Technical Specifications
Measured parameters Dust
Technology ProScatter™ Backscatter
Measurement / Monitoring capability <0 – 500 mg/m3*
Stack / Duct diameter suitability up to 10m
Flue gas temperature up to 400°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter /
Coalescent Filter /
Cyclone YES
Electrostatic Precipitator (ESP) YES
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
Sensor variants Stainless Steel
Hastelloy® corrosion resistant
QA checks YES
*Application dependant
Technical data
Measurement capability <0 – 500 mg/m3
Stack Temperature Ranges -20°C-250°C, up to 400°C option
Functionality and QA Checks Functionality and QA Checks
Contamination Check Automatic
Flue Gas Blocker YES
Networked system Option
Enclosure Protection Rating IP65
logo-tuv-qal1-QAL360-0000053808_en
  • The measurement system was tested by TÜV Rheinland Energy GmbH in accordance with the European Standards EN 15267 Part 1, 2 and 3 and is QAL1 certified according to EN 14181
  • MCERTs certified